Related Experiment Video
Updated: Aug 11, 2026

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Aqueous misdirection syndrome: a complication of neodymium: YAG posterior capsulotomy
L Mastropasqua1, M Ciancaglini, P Carpineto
1Institute of Ophthalmology, University of Chieti, Italy.
Abstract:
A 50-year-old, white, pseudophakic man who had a neodymium:YAG (Nd:YAG) posterior capsulotomy for capsule opacification developed a persistent rise in intraocular pressure (IOP) associated with a flat anterior chamber. Full-thickness patent iridotomy performed with an Nd:YAG laser did not reduce IOP. A-scan ultrasonography showed aqueous pockets in the vitreous, leading to a diagnosis of malignant glaucoma. Medical therapy comprising atropine, phenylephrine, mannitol, and acetazolamide normalized IOP and resolved the clinical findings.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment