Related Experiment Videos

[Outcome of Doppler parameters of left ventricular systolic function during atrial stimulation as a function of

C Selton-Suty1, J Anconina, P Buffet

  • 1Service de cardiologie B, CHU Nancy-Brabois, Vandoeuvre-lès-Nancy.

Archives Des Maladies Du Coeur Et Des Vaisseaux
|November 1, 1993
PubMed

Insights

Transesophageal atrial pacing significantly impacts left ventricular outflow tract Doppler parameters in coronary artery disease patients, unlike in healthy individuals. These findings highlight differences in cardiac response to pacing between healthy and diseased hearts.

Area of Science:

  • Cardiology
  • Cardiovascular Physiology

Background:

  • Transesophageal atrial pacing is a method to assess cardiac function.
  • Doppler echocardiography provides key parameters of left ventricular outflow tract (LVOT) flow.

Purpose of the Study:

  • To investigate the effects of transesophageal atrial pacing on LVOT Doppler parameters in patients with and without coronary artery disease (CAD).

Main Methods:

  • Eighty-nine patients (8 with normal coronary arteries, 21 with CAD) underwent transesophageal atrial pacing, increasing heart rate from 90 to 130 bpm.
  • LVOT Doppler parameters including maximal velocity (V max), velocity-time integral (VTI), mean acceleration (Acc), and acceleration force (AF) were measured.

Main Results:

  • In CAD patients, pacing decreased V max and AF, while Acc remained stable. In controls, V max and AF were unchanged, but Acc increased.
  • The velocity-time integral (VTI) decreased significantly in both groups.
  • Percentage variations in V max, Acc, and AF differed significantly between CAD patients and controls.

Conclusions:

  • Transesophageal atrial pacing elicits distinct changes in LVOT Doppler parameters in patients with coronary artery disease compared to healthy individuals.
  • These findings suggest impaired myocardial response to increased heart rate in the presence of coronary stenoses.