Validation of the low dose short insulin tolerance test for evaluation of insulin sensitivity
S V Gelding1, S Robinson, S Lowe
1Unit of Metabolic Medicine, St Mary's Hospital Medical School, London, UK.
Objective:
The assessment of insulin sensitivity requires an accurate and reproducible technique. The short insulin tolerance test is a simple and rapid method for screening large numbers of subjects when the fasting glucose level is normal. Conventionally, an insulin dose of 0.1 units/kg is used, but this may result in symptomatic hypoglycaemia in healthy thin subjects who are insulin sensitive. In order to overcome this problem we have employed a lower dose of insulin and have studied the reproducibility of this modified technique comparing it with the euglycaemic hyperinsulinaemic clamp.
Design:
Subjects were studied on two separate occasions, once by a short insulin tolerance test and on a second occasion by either a euglycaemic hyperinsulinaemic clamp (insulin infusion of 40 mU/m2/min) or a repeat short insulin tolerance test.
Patients:
Eleven healthy subjects were studied twice with a short insulin tolerance test. A further 10 healthy subjects received a short insulin tolerance test on one day and a euglycaemic hyperinsulinaemic clamp study on another occasion.
Measurements:
Insulin sensitivity was measured in the short insulin tolerance test using the slope of arterialized blood glucose concentration from 3 to 15 minutes after an intravenous bolus of short-acting insulin, 0.05 units/kg body weight. In the clamp study, insulin sensitivity was derived from the average amount of glucose infused at steady state (M) and the mean plasma insulin level (I).
Results:
In the short insulin tolerance test no subject developed symptomatic or biochemical hypoglycaemia, defined as a blood glucose < 2.2 mmol/l. The (mean +/- SEM) insulin sensitivities for the 11 subjects studied twice were 174 +/- 10 and 179 +/- 11 mumol/l/min with a coefficient of variation of 6.9 +/- 2.6%. There was a close correlation between insulin sensitivity derived from the short insulin tolerance test and that obtained from the euglycaemic clamp studies (so-called M/I ratio) in the same subjects (r = 0.81; P < 0.005).
Conclusion:
The short insulin tolerance test employing 0.05 units/kg insulin is a safe, valid and reproducible method for the assessment of insulin sensitivity.