The response of atrioventricular junctional tissue to temperature
Related Experiment Video
Updated: Nov 10, 2026

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
1First Department of Internal Medicine, School of Medicine, Tokyo Medical and Dental University, Japan.
To determine the optimal temperature for catheter heat mapping without damaging cardiac tissue, we studied the electrophysiologic and histologic responses of the atrioventricular (AV) conduction system exposed to a specific range of temperatures. In 18 closed-chest dogs, an electrode catheter with a thermistor, tip was positioned transvenously at the AV junction. Radiofrequency current (RFC) was applied in incremental temperature steps until transient 2nd-degree AV block was induced. Catheter tip temperature (CTT) was measured at each step. RFC was immediately discontinued when AV block occurred. AV conduction was evaluated before and 4 weeks after the procedure. Acute transient 2nd-degree AV block was induced in 45 applications, during which the average CTT was 48.7 +/- 2.7 degrees C. In another 40 applications in which 2nd degree AV block was not induced, the average CTT was significantly lower [46.3 +/- 2.5 degrees C] (p < 0.001). Eleven of 16 dogs showed acute 2nd-degree AV block, but had normal AV conduction at 4 weeks (Group A). In the other 5 dogs, 1st-degree AV block was seen at 4 weeks (Group B). The lowest CTTs in Groups A and B were 45 and 49 degrees C, respectively. Histologic findings in 2 dogs from Group A revealed that 10-15% (by area) of the AV node was fibrotic. These findings suggest that the induction of fully reversible AV block can be achieved by titration of RFC, during the application of RFC to the AV junction. In conclusion, RF energy was used to produce a tip temperature of between 45 degrees C and 49 degrees C, which induced reversible and significant interruption of conduction of in tissue in the AV junction, and presumably also in target sites in clinical RF ablation.
To determine the optimal temperature for catheter heat mapping without damaging cardiac tissue, we studied the electrophysiologic and histologic responses of the atrioventricular (AV) conduction system exposed to a specific range of temperatures. In 18 closed-chest dogs, an electrode catheter with a thermistor, tip was positioned transvenously at the AV junction. Radiofrequency current (RFC) was applied in incremental temperature steps until transient 2nd-degree AV block was induced. Catheter tip temperature (CTT) was measured at each step. RFC was immediately discontinued when AV block occurred. AV conduction was evaluated before and 4 weeks after the procedure. Acute transient 2nd-degree AV block was induced in 45 applications, during which the average CTT was 48.7 +/- 2.7 degrees C. In another 40 applications in which 2nd degree AV block was not induced, the average CTT was significantly lower [46.3 +/- 2.5 degrees C] (p < 0.001). Eleven of 16 dogs showed acute 2nd-degree AV block, but had normal AV conduction at 4 weeks (Group A). In the other 5 dogs, 1st-degree AV block was seen at 4 weeks (Group B). The lowest CTTs in Groups A and B were 45 and 49 degrees C, respectively. Histologic findings in 2 dogs from Group A revealed that 10-15% (by area) of the AV node was fibrotic. These findings suggest that the induction of fully reversible AV block can be achieved by titration of RFC, during the application of RFC to the AV junction. In conclusion, RF energy was used to produce a tip temperature of between 45 degrees C and 49 degrees C, which induced reversible and significant interruption of conduction of in tissue in the AV junction, and presumably also in target sites in clinical RF ablation.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Thermosensation
Responses to Heat and Cold Stress
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Electrophysiology of Normal Cardiac Rhythm