Related Experiment Video
Updated: Oct 2, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Liquid ventilation provides uniform distribution of perfluorocarbon in the setting of respiratory failure
R B Hirschl1, M C Overbeck, A Parent
1Department of Surgery, University of Michigan, Ann Arbor.
Background:
We evaluated the effect of perfluorocarbon liquid ventilation (LV) on gas exchange and pulmonary function in the setting of respiratory failure and the distribution of the ventilating medium during LV when compared to gas ventilation (GV).
Methods:
Ten sheep, 17.3 +/- 4.2 kg in weight, underwent oleic acid induction of lung injury followed by either GV (n = 5) or perfluorocarbon LV (n = 5). After 1 hour animals were killed, and chest computed tomographic (CT) imaging was performed. Average CT attenuation number was assessed as an indicator of the distribution of gas or perfluorocarbon in the dependent (posterior) and nondependent (anterior) zones of the lung (air = -1000; soft tissue = 0; perfluorocarbon = +2300 Hounsfield units [H]).
Results:
Significant increases in PaO2 (LV = 298 +/- 76 mm Hg, GV = 43 +/- 18 mm Hg, p < 0.001), SvO2 (LV = 74% +/- 6%, GV = 32% +/- 18%, p < 0.01), and lung compliance (LV = 1.65 +/- 0.50 ml/cm H2O/kg, GV = 0.58 +/- 0.06 ml/cm H2O/kg, p < 0.01) were observed. Significant decreases in physiologic shunt (LV = 24% +/- 6%, GV = 62% +/- 14%, p < 0.01) were noted. CT attenuation data showed the presence of minimal gas ventilation in the dependent regions during GV although the nondependent regions remained well aerated (CT attention number during GV: ND = -654 +/- 160 H; D = -92 +/- 160 H, p < 0.0001). During LV, there was a fairly homogenous distribution of perfluorocarbon in the lungs (CT attenuation number during LV: D = 1071 +/- 330 Hounsfield units; ND = 1112 +/- 287 Hounsfield units; p = 0.240). Lung biopsy analysis in the LV animals was consistent with a reduction in intraalveolar hemorrhage, intraalveolar edema, and the inflammatory infiltrate.
Conclusions:
On the basis of the data, we conclude that in this lung injury model, (1) the distribution of the ventilating medium is uniform during LV when compared to GV, (2) LV improves gas exchange and pulmonary function, and (3) histologic evidence of lung injury is reduced after LV when compared to GV.
More Related Videos
09:28Intravital Widefield Fluorescence Microscopy of Pulmonary Microcirculation in Experimental Acute Lung Injury Using a Vacuum-Stabilized Imaging System
Published on: April 6, 2022
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...