Related Experiment Videos
Design criteria for prompt radiation limits on the relativistic heavy ion collider site
A Stevens1, S Musolino, M Harrison
1Brookhaven National Laboratory, RHIC Project, Upton, NY 11973.
Abstract:
The Relativistic Heavy Ion Collider (RHIC) is a superconducting colliding beam accelerator facility that is currently under construction. Relatively small amounts of energy depositing in the coils of superconducting magnets can result in a "quench," the irreversible transition to the normal resistive state. The quench limit of superconducting magnets, therefore, constrains local beam loss throughout the injection, acceleration, and storage cycles to extremely low levels. From a practical standpoint, it follows that there is essentially no prompt radiation in most regions due to normal operations. The design of shielding is, therefore, principally driven by the consequences of a single pulse fault at full energy in one of the two storage rings. Since there are no regulatory requirements or guidance documents that prescribe radiological performance goals for this situation, the RHIC Project has proposed a scheme to classify the various areas of the RHIC complex based on Design Basis Accident faults. The criteria is then compared to existing regulatory requirements and guidance recommendations.