Related Experiment Video
Updated: Sep 28, 2026

Transplantation of Pulmonary Valve Using a Mouse Model of Heterotopic Heart Transplantation
Published on: July 23, 2014
Atrioventricular valve replacement with the Hancock porcine xenograft: a five year clinical experience
Since July, 1970, 111 patients have undergone mitral and/or tricuspid valve replacement with a glutaraldehyde-fixed porcine xenograft mounted on a flexible stent; 41 of these patients also had aortic valve replacement with a Starr-Edwards or Bjork-Shiley valve, and 85 patients presently are alive. Cumulative follow-up totals 2,060 months, with 16 patients followed more than 4 years. Anticoagulants have not been administered postoperatively, and one patient has had a systemic embolus. Postoperative hemodynamic assessments have been carried out in 54 patients, and in either the mitral or tricuspid position the valve was shown to have good hydraulic function. Significant mitral regurgitation, secondary to prosthetic dysfunction, occurred in one patient 56 months following implantation. Progressive prosthetic stenosis has not occurred, and hemolysis or anemia of clinical significance has not been observed as a consequence of the use of the use of the xenograft. To date, these clinical and hemodynamic data indicate that the glutaraldehyde-fixed xenograft, mounted on a flexible stent, is the prosthesis of choice for mitral and tricuspid valve replacement.
Since July, 1970, 111 patients have undergone mitral and/or tricuspid valve replacement with a glutaraldehyde-fixed porcine xenograft mounted on a flexible stent; 41 of these patients also had aortic valve replacement with a Starr-Edwards or Bjork-Shiley valve, and 85 patients presently are alive. Cumulative follow-up totals 2,060 months, with 16 patients followed more than 4 years. Anticoagulants have not been administered postoperatively, and one patient has had a systemic embolus. Postoperative hemodynamic assessments have been carried out in 54 patients, and in either the mitral or tricuspid position the valve was shown to have good hydraulic function. Significant mitral regurgitation, secondary to prosthetic dysfunction, occurred in one patient 56 months following implantation. Progressive prosthetic stenosis has not occurred, and hemolysis or anemia of clinical significance has not been observed as a consequence of the use of the use of the xenograft. To date, these clinical and hemodynamic data indicate that the glutaraldehyde-fixed xenograft, mounted on a flexible stent, is the prosthesis of choice for mitral and tricuspid valve replacement.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:56An Ex Vivo Porcine Model for Hydrodynamic Testing of Experimental Aortic Valve Procedures and Novel Medical Devices
Published on: August 25, 2023