Neisseria gonorrhoeae penicillin susceptibility: a comparison of three testing methods

P A Hitchcock1

  • 1Department of Medical Microbiology, St George's Hospital, London, England, UK.

Insights

The 3-disc diffusion method and E-Test are reliable for detecting Neisseria gonorrhoeae penicillin resistance. Both methods correlate well with the reference agar dilution, making them suitable for routine laboratory use.

Area of Science:

  • Microbiology
  • Antimicrobial Susceptibility Testing

Background:

  • Penicillin resistance in Neisseria gonorrhoeae poses a significant public health challenge.
  • Accurate and efficient susceptibility testing is crucial for guiding treatment decisions.

Purpose of the Study:

  • To compare the performance of the 3-disc diffusion method and the PDM Epsilometer (E-Test) against the agar plate dilution reference method.
  • To evaluate the suitability of these methods for routine testing of N. gonorrhoeae penicillin susceptibility.

Main Methods:

  • Agar plate dilution as the reference method.
  • Testing of 46 clinical isolates and 5 reference strains of N. gonorrhoeae.
  • Comparison of results obtained from the 3-disc diffusion method and the E-Test.

Main Results:

  • Both the 3-disc diffusion method and the E-Test demonstrated a high level of correlation with the reference method.
  • Both methods effectively detected high and moderate levels of penicillin resistance.
  • The E-Test provided a more precise differentiation of moderate resistance levels.

Conclusions:

  • The 3-disc diffusion method and the E-Test are suitable for routine N. gonorrhoeae penicillin susceptibility testing.
  • The E-Test offers an advantage in characterizing moderate resistance, potentially aiding diagnostic laboratories.