Hemispheric differences in the interference among components of compound gratings
Related Experiment Video
Updated: Sep 20, 2026

How to Create and Use Binocular Rivalry
Published on: November 10, 2010
F L Kitterle1, S Christman, J Conesa
1Department of Psychology, Stephen F. Austin State University, Nacogdoches, TX 75962.
Abstract:
The relationship between local/global and high/low spatial-frequency processing in hemispheric asymmetries was explored. Subjects were required to judge the orientation of a high- or low-spatial-frequency component of a compound grating presented in the left visual field (LVF) or right visual field (RVF). In Experiment 1, attention was focused on one or the other component. A signal detection analysis indicated that sensitivity (d') to the high-spatial-frequency target was reduced more by the presence of the low-spatial-frequency component when both were presented in the LVF rather than in the RVF. In Experiment 2, subjects determined whether a target orientation was present, independent of spatial frequency at only a single level (i.e., at the high- or low-spatial-frequency level), as opposed to both or neither level. An RVF/LH (left hemisphere) advantage was found when the decision was based on the orientation of the high-frequency component. The asymmetrical influence of visual field of presentation and spatial frequency upon sensitivity is discussed in terms of hemispheric differences in the magnitude of inhibition between spatial-frequency channels and in the role of transient channel activity to capture and direct higher order attentional processes.
Related Concept Videos
Interference and Diffraction
Stereoisomerism
Isomers are different chemical species that have the same chemical formula.
Transition metal complexes often exist as geometric isomers, in which the same atoms are connected through the same types of bonds but with differences in their orientation in space. Coordination complexes with two different ligands in the cis and trans positions from a ligand of interest form isomers. For example, the octahedral [Co(NH3)4Cl2]+ ion has two isomers (Figure 1) In the cis...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Anatomy of the Eyeball
Color Vision

