Related Experiment Video
Updated: Jul 11, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Oxygen saturation during endoscopic retrograde cholangiopancreatography: a comparison of two protocols of oxygen
J D Rigg1, T C Watt, D E Tweedle
1Department of Anaesthetics, Withington Hospital, Manchester.
Abstract:
Patients having endoscopic retrograde cholangiopancreatography (ERCP) are generally elderly and require sedation while in the prone position. These factors may be expected to aggravate any risk of arterial hypoxia. This study evaluated two protocols of oxygen administration, one with and one without pre-oxygenation. In 25 patients in whom pre-oxygenation with 4 litres/minute for five minutes before sedation was used, followed by continuous oxygen administration, arterial oxygen saturation did not fall below 90% at any stage during the procedure. By contrast, in 25 patients who were not pre-oxygenated oxygen saturation fell below 90% in nine (36%). As expected, hypoxia occurred most frequently during the early stages of sedation and endoscope insertion. Hypoxia did not occur in association with operations such as sphincterotomy, stone extraction or stent insertion. This study confirms that arterial hypoxia is a common event during ERCP and can be completely prevented by pre-oxygenation with four litres of oxygen given intranasally for five minutes before sedation.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Endoscopic Procedures V: ERCP