Related Experiment Video
Updated: Aug 16, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Adverse environmental conditions in the respiratory and medical ICU settings
T J Meyer1, S E Eveloff, M S Bauer
1Department of Medicine, Rhode Island Hospital, Providence 02903.
Abstract:
Sleep deprivation and fragmentation occurring in the hospital setting may have a negative impact on the respiratory system by decreasing respiratory muscle function and ventilatory response to CO2. Sleep deprivation in a patient with respiratory failure may, therefore, impair recovery and weaning from mechanical ventilation. We postulate that light, sound, and interruption levels in a weaning unit are major factors resulting in sleep disorders and possibly circadian rhythm disruption. As an initial test of this hypothesis, we sampled interruption levels and continuously monitored light and sound levels for a minimum of seven consecutive days in a medical ICU, a multiple bed respiratory care unit (RCU) room, a single-bed RCU room, and a private room. Light levels in all areas maintained a day-night rhythm, with peak levels dependent on window orientation and shading. Peak sound levels were extremely high in all areas representing values significantly higher than those recommended by the Environmental Protection Agency as acceptable for a hospital environment. The number of sound peaks greater than 80 decibels, which may result in sleep arousals, was especially high in the intensive and respiratory care areas, but did show a day-night rhythm in all settings. Patient interruptions tended to be erratic, leaving little time for condensed sleep. We conclude that the potential for environmentally induced sleep disruption is high in all areas, but especially high in the intensive and respiratory care areas where the negative consequences may be the most severe.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-IV
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...

