Related Experiment Videos
Changes in arterial wall compliance after endovascular stenting
1Department of Surgery, Harbor-UCLA Medical Center, Torrance 90509-9823.
Journal of Vascular Surgery
|May 1, 1994
Summary
Endovascular stenting significantly reduces arterial compliance in canine iliac arteries shortly after implantation. This loss of flexibility is linked to a fibrous reaction and neointimal hyperplasia, diminishing the benefits of compliant stents.
Area of Science:
- Vascular biology
- Biomedical engineering
- Interventional cardiology
Background:
- The arterial wall's response to endovascular stenting post-angioplasty is not fully understood.
- In situ changes in the elastic properties of stented vessels remain largely unknown.
Purpose of the Study:
- To investigate vascular compliance in canine iliac arteries before and after intravascular ultrasound-guided self-expandable metallic stent deployment.
- To assess the in situ elastic properties of stented arteries over time.
Main Methods:
- Vascular compliance was measured in 11 normal canine iliac arteries using an absolute induction angiometer.
- Measurements were taken before stenting, immediately after, and at 1, 2, and 4 weeks post-deployment in nine animals.
- The angiometer utilized a catheter-based wire loop probe to measure diameter changes induced by systolic/diastolic pressure variations.
Main Results:
- Mean arterial compliance decreased from 4.4 +/- 2.1 to 1.9 +/- 2.0 (x 10(-2) diameter %/mm Hg) immediately after stenting.
- Stented arteries showed reduced expansile properties and became noncompliant as early as 1 week post-deployment.
- Diminished compliance correlated with a periadventitial fibrous reaction; neointimal hyperplasia was present but did not obstruct flow, and all vessels remained patent.
Conclusions:
- The inherent flexibility of radially compliant stents is lost relatively quickly after implantation in nonatherosclerotic canine arteries.
- A significant periadventitial fibrous reaction contributes to the loss of vascular compliance post-stenting.
- Despite neointimal hyperplasia, stented iliac arteries remained patent without thrombus formation.