X-ray tube potential, filtration, and detector considerations in dual-energy chest radiography
1Department of Radiology, University of Alabama at Birmingham 35233.
Abstract:
The effect of x-ray tube potential and prepatient and interdetector filtration in single exposure dual energy chest imaging has been studied employing a carefully benchmarked model. The analysis utilized published methodology. Noise in simulated lung and mediastinum fields of the aluminum (bone) and Lucite (soft tissue) images were studied at fixed entrance skin exposure (ESE) for commonly employed sandwich detector and sandwich imaging plate configurations. Our results indicate noise in the lung increases slowly with tube potential above 120 kVp, while noise in the mediastinum decreases rapidly. Also, at high tube potential (> or = 120 kVp) adding moderate amounts of prepatient K-edge filtration (approximately equal to 100 mg/cm2) while optimizing imaging conditions for the lung tends to decrease noise in the lungs by approximately equal to 30% while increasing noise in the mediastinum by a similar amount. Without K-edge prepatient filtration, noise in the lung is minimized with Cu interdetector filter weights near 400 mg/cm2. In the mediastinum noise is minimized with heavier interdetector filter and prepatient K-edge filter weights. Prepatient K-edge filter weights that minimize image noise in either field can increase the tube loading by factors ranging from 10 to 10(10). Systems designed with sandwich detectors using commercially available phosphors and coating weights can produce contrast-to-noise ratios (CNRs) as high as 50% of the theoretical limit (defined as an optimized system with a totally absorbing rear detector).
Related Concept Videos
X-ray Imaging
Determination of Crystal Structures
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...