Measurement of cardiac output with the Quantascope, a novel Doppler device: comparison with thermodilution
S J Cross1, H S Lee, K Jennings
1Department of Cardiology, Aberdeen Royal Infirmary, Scotland, U.K.
Abstract:
The Quantascope is a novel non-imaging echo-Doppler device designed to measure cardiac output. We have compared this device with thermodilution. Twenty-five patients with suspected coronary artery disease undergoing diagnostic coronary arteriography simultaneously had cardiac output measured with the Quantascope and with thermodilution. Doppler systematically underestimated cardiac output, when compared with thermodilution, by a mean (SD) of 0.9 (1.5) l.min-1 (P < 0.01). The cardiac output derived by the Doppler technique did not correlate with that derived by thermodilution (r = 0.36, P = NS). Compared with the currently accepted reference technique of thermodilution, we found measurement of cardiac output by the Quantascope to be inaccurate: this contradicts previous reports.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...