Related Experiment Video
Updated: Feb 12, 2026

A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Path and extent of cross-bridge rotation during muscle contraction
K Ajtai1, D J Toft, T P Burghardt
1Department of Biochemistry and Molecular Biology, Mayo Foundation, Rochester, Minnesota 55905.
Abstract:
The angular distribution of myosin cross-bridges in muscle fibers was investigated in four physiological states using a multiple probe analysis of varied extrinsic probes of the cross-bridge [Burghardt & Ajtai (1994) Biochemistry (preceding paper in this issue)]. The analysis combines data of complementary techniques from different probes giving the highest possible angular resolution. Four extrinsic probes of the fast reactive sulfhydryl (SH1) on myosin subfragment 1 (S1) were employed. Electron paramagnetic resonance (EPR) spectra from paramagnetic probes, deuterium- and 15N-substituted for greater sensitivity to orientation, on S1 were measured when the protein was freely tumbling in solution and when it was decorating muscle fibers. The EPR spectra from labeled S1 tumbling in solution were measured at X- and Q-band microwave frequencies to uniquely specify the orientation of the probe relative to the S1 principal hydrodynamic frame. The EPR spectra from labeled S1 decorating muscle fibers in rigor and in the presence of MgADP were measured at X-band and used in the multiple probe analysis of cross-bridge orientation. The time-resolved fluorescence anisotropy decay (TRFAD) of fluorescent probes on S1 was measured when the protein was freely tumbling in solution, and fluorescence polarization (FP) intensities from fluorescent probes modifying SH1 in intact muscle fibers were measured for fibers in rigor, in the presence of MgADP, in isometric contraction, and in relaxation at low ionic strength. The TRFAD measurements limit the range of possible orientations of the probe relative to the S1 principal hydrodynamic frame. The FP intensity measurements were used in the multiple probe analysis of cross-bridge orientation. The combination of the EPR and FP data determined a highly resolved cross-bridge angular distribution in rigor, in the presence of MgADP, in isometric contraction, and in relaxation at low ionic strength. These findings confirm earlier observations of a rigid body rotation of the SH1 region in the myosin head group upon physiological state changes and indicate the path and extent of cross-bridge rotation during contraction. The rotation of the cross-bridge is visualized with computer-generated space-filling models of actomysin in six states of the contraction cycle.
Related Concept Videos
Muscle Contraction
Cross-bridge Cycle
Muscle Contraction
Smooth Muscle Contraction
The onset of contraction is triggered by an increase in calcium ions within the sarcoplasm, similar to the process in striated muscle. However, smooth muscles have a relatively smaller reservoir of the sarcoplasmic...
Energy Supply for Muscle Contraction
Isotonic and Isometric Muscle Contractions
Isotonic contractions
Isotonic contractions occur when a muscle changes length while...

