Spectra of data sampled at frequency-modulated rates in application to cardiovascular signals: Part 1. Analytical
B J TenVoorde1, J C Faes, O Rompelman
1Vrije Universiteit, AZVU-Poli, Amsterdam, The Netherlands.
Insights
Pulse frequency modulation (PFM) from heart rate variations can create spurious components in cardiovascular signal analysis. Spectral analysis of systolic blood pressure may include up to 30% artifact due to PFM.
Area of Science:
- Biomedical Engineering
- Signal Processing
- Cardiovascular Physiology
Background:
- Beat-to-beat cardiovascular signals, like systolic pressure, are time series.
- These signals exhibit pulse amplitude modulation (PAM) and pulse frequency modulation (PFM).
- PFM, caused by heart rate variability, leads to non-uniform time spacing, complicating spectral analysis.
Purpose of the Study:
- To derive an analytical expression for the spectrum of sinusoids sampled by a pulse frequency modulator.
- To understand and quantify the influence of PFM on the spectral analysis of PAM signals.
- To assess the impact of heart rate modulation on the accuracy of cardiovascular signal quantification.
Main Methods:
- Developed an analytical expression for the spectrum of sinusoids modulated by a linear integral pulse frequency modulator (IPFM).
- Analyzed the resulting spectral components based on the interplay between PAM and PFM frequencies.
- Investigated the appearance of spectral components around the mean pulse frequency (mean heart rate).
Main Results:
- Two primary spectral components emerge at the difference and sum of PFM and PAM frequencies (fp ± fx).
- The amplitudes of these components are directly proportional to the PFM modulation depth.
- A cluster of spectral components appears around the mean pulse frequency (fo), specifically at fo-nfp ± fx, potentially interfering with the true signal band.
Conclusions:
- PFM introduces significant artifacts into the spectral analysis of cardiovascular signals.
- The amplitude spectrum of systolic blood pressure can contain 20-30% spurious components due to heart rate modulation.
- Accurate quantification of PAM requires accounting for the effects of PFM.
Abstract:
Beat-to-beat cardiovascular signals, e.g. a series of systolic pressure values, can be considered as time series which are pulse amplitude modulated (PAM) and pulse frequency modulated (PFM). The latter process, due to variations in heart rate, causes the series to become non-uniformly spaced in time. If PAM is to be quantified by spectral analysis, the influence of PFM must be known. An analytical expression is therefore derived for the spectrum of sinusoids which are sampled according to the output event series of a linear integral pulse frequency modulator (IPFM). We conclude that two spectral components arise at the difference and sum of the PFM and PAM frequencies, fp +/- fx, with amplitudes proportional to the PFM modulation depth. These components appear as a DC component and as a first harmonic if both modulating frequencies are equal. In addition, a cluster of spectral components appears around the mean pulse frequency fo (i.e. mean heart rate), at frequencies fo-nfp +/- fx, which may leak into the signal band. From these theoretical considerations, we conclude that the amplitude spectrum of a sinusoidally varying systolic blood pressure series can contain up to 20-30% spurious components, owing to the heart rate modulation process.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Discrete Fourier Transform
Sampling Theorem
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Upsampling
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2. The spectrum...