Counterpulsation: historical background, technical improvements, hemodynamic and metabolic effects
1University of Athens School of Medicine, Department of Clinical Therapeutics, Alexandra Hospital, Greece.
Cardiology
|January 1, 1994
Summary
Intraaortic balloon counterpulsation (IABP) improves hemodynamic function and reduces myocardial infarction size. Newer devices and techniques enhance IABP
Area of Science:
- Cardiovascular Physiology
- Biomedical Engineering
- Mechanical Circulatory Support
Background:
- Intraaortic balloon counterpulsation (IABP) principles remain unchanged since 1962.
- IABP is a critical tool in managing acute cardiovascular conditions.
Purpose of the Study:
- To review the established hemodynamic benefits of IABP.
- To explore advancements in IABP technology and alternative counterpulsation devices.
Main Methods:
- Review of experimental studies on IABP's physiological effects.
- Evaluation of new IABP delivery systems and percutaneous insertion techniques.
- Assessment of paraaortic counterpulsation devices in chronic experiments and clinical cases.
Main Results:
- IABP significantly increases aortic diastolic pressure, cardiac output, and blood flow, while decreasing cardiac workload and myocardial oxygen consumption.
- IABP reduces myocardial infarction size.
- Paracortic counterpulsation devices demonstrate superior efficacy and biocompatibility in chronic settings.
Conclusions:
- IABP provides significant salutary hemodynamic effects, validated by extensive experimental data.
- Technological advancements are making IABP safer and more accessible.
- Further research is warranted to fully understand the potential of counterpulsation techniques, including newer devices.
Related Concept Videos
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.
Pulse
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...
The pulse serves as a clinical indicator...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
In a cardiovascular examination, inspection and palpation are crucial for identifying abnormalities.
Abnormal findings observed during an inspection
Abnormal findings observed during an inspection