Prospective comparison of T2-weighted fast spin-echo, with and without fat suppression, and conventional spin-echo
L H Schwartz1, S E Seltzer, C M Tempany
1Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Mass.
Purpose:
To evaluate use of fast spin-echo (FSE) magnetic resonance imaging with and without fat suppression in the liver and upper abdomen.
Materials And Methods:
Conventional spin-echo (SE) T2-weighted, FSE T2-weighted, and fat-suppressed FSE T2-weighted images from 37 patients strongly suspected to have focal hepatic lesions were evaluated.
Results:
Quantitative analysis demonstrated that fat-suppressed FSE imaging had the highest lesion-liver contrast-to-noise ratio; conventional SE imaging, the lowest. In a qualitative analysis, FSE imaging was preferred. In a rank order analysis, FSE imaging was preferred 83% of the time and fat-suppressed FSE imaging 17% of the time as regards overall image quality; fat-suppressed FSE imaging was preferred 64% of the time, FSE imaging 23% of the time, and conventional SE imaging 13% of the time as regards signal abnormality detection.
Conclusion:
FSE imaging with and without fat suppression is a potentially useful pulse sequence for evaluating the upper abdomen.