Calibration of albumin-fatty acid binding constants measured by heptane-water partition
F J Burczynski1, S M Pond, C K Davis
1Department of Medicine, University of California, San Francisco 94143-0538.
Abstract:
Most measurements of binding affinity of albumin for long-chain fatty acids are based on heptane-water partition. In this method, equilibrium partition of fatty acid between heptane and an albumin-containing buffer is calibrated using the partition ratio between heptane and buffer in the absence of protein. In the current study, we used a variety of techniques to examine potential problems with this approach. Hydrophobic impurities in commercial [3H]palmitate preparations were incompletely removed by standard purification techniques. These impurities contributed from 5% of the total radioactivity in the heptane phase at low albumin concentrations (5 microM) to 62% at higher albumin concentrations (500 microM), thus confounding determination of binding affinity. These were identified by gas chromatography/mass spectroscopy as radio-labeled glycerol monopalmitate and monostearate. When albumin was not present, the partition ratio was similar to values reported by others. However, our results varied by a factor of four (265-1,119) depending on how the solutions were prepared. Although a true equilibrium partition must not depend on starting conditions, the partition ratio after 24-72 h was > 2x as large when tracer [3H]palmitate was added to the heptane phase than when it was added to the aqueous phase. Results also depended on the relative volumes of heptane and buffer used, approaching a maximum of 1,445 +/- 112 for very low heptane/buffer volume ratios. Much of this variability was due to hydrophilic impurities in [3H]palmitate, which ranged from 0.2 to 1.2% in commercial lots down to 0.1-0.5% after alkaline ethanol extraction and < 0.05% after thin-layer chromatography (TLC).(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
The Equilibrium Binding Constant and Binding Strength
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...