End-tidal oxygen measurement compared with patient factor assessment for determining preoxygenation time
Related Experiment Video
Updated: Aug 11, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
H A Machlin1, P S Myles, C B Berry
1Department of Anaesthesia, Alfred Hospital, Melbourne, Victoria.
Abstract:
Time to adequate preoxygenation was assessed in 200 elective surgical patients, using measurement of end-tidal oxygen concentration. A variety of patient factors were assessed as to their ability to predict the time required to preoxygenate a patient. Of the 200 patients, 23 (11.5%) were unable to be adequately preoxygenated; most of these cases were due to a poor mask fit. The average time for preoxygenation was 154 seconds (range 43-364 seconds). Of those patients who could be preoxygenated, 46 (23%) required more than three minutes. Although a regression equation could be constructed to calculate time required for preoxygenation, the wide standard errors of the coefficients preclude a clinically useful predictive equation. We thus found that we could not accurately predict time required for preoxygenation and that a routine three minutes preoxygenation may not be sufficient for many patients. However, the measurement of end-tidal oxygen concentration is a very useful method of determining the end-point for preoxygenation.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: