Related Experiment Video
Updated: Aug 13, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Excellent long-term results of cardiac valve replacement with the St Jude Medical valve prosthesis
J A Smith1, G W Westlake, M H Mullerworth
1Cardiothoracic Surgery Unit, Royal Melbourne Hospital, Victoria, Australia.
Background:
A retrospective review of the performance of the St Jude Medical valve prosthesis over a 12-year period was undertaken.
Methods And Results:
Between 1978 and 1990, 696 St Jude Medical valve prostheses (351 isolated aortic, 191 isolated mitral, 64 double aortic/mitral) were implanted into 616 patients (mean age, 55 years). Concomitant coronary artery graft surgery was performed in 18%. During mid-1991, follow-up was conducted, yielding a 97% completion (16 lost), for a total of 3075 cumulative patient-years (mean, 5.0 years). Early (30-day) mortality rates were 3.1%, 5.2%, and 6.4% after aortic, mitral, and double valve replacements, respectively. The 5-year actuarial survival rates were 94.1 +/- 1.3%, 85.8 +/- 2.7%, and 86.3 +/- 4.6% and those for 10 years were 89.6 +/- 1.9%, 72.9 +/- 6.1%, and 83.0 +/- 5.4%, respectively. There were no structural valve failures. Anticoagulant-related hemorrhage was the most common valve-related complication (28 events, 0.9% per patient-year), with three being fatal. Thromboembolism (13 events) occurred at a rate of 0.5% per patient-year (0.6% aortic, 0.3% mitral, 0.3% double). All of the nonstructural deteriorations (10 events, 0.3% per patient-year) were paravalvular leaks, including 3 aortic valve replacements in patients who developed hemolytic anemia. There was 1 valve thrombosis (0.03% per patient-year). Patients undergoing coronary artery graft surgery had lower survival and higher complication rates than patients without coronary artery graft surgery. There was a significant improvement (P < .001) in New York Heart Association functional class for the entire patient population.
Conclusions:
The St Jude Medical valve prosthesis has performed well in all positions over a 12-year period, with an acceptably low incidence of valve-related complications.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis III: Medical Management