High porosity PTFE improves endothelialization of arterial grafts without increasing early thrombogenicity
B L Cameron1, H Tsuchida, T P Connall
1Department of Surgery, University of California, Irvine Medical Center, Orange 92668.
Objective:
High porosity (HP) (90 micron internodal distance) PTFE grafts were implanted into the carotid and femoral arteries of dogs to investigate early thrombogenicity, patency, and endothelialization.
Experimental Design:
Standard PTFE (STD) grafts (30 micron internodal distance) were used as controls. 12 HP and 12 STD grafts were implanted into 6 dogs. Indium-111 labeled platelets were infused intravenously after graft implantation. A graft platelet accumulation index (GPAI) was calculated as the ratio of radioactive emission from the PTFE grafts excised at 48 hours to the emission from a native arterial segment. Another 12 HP and 12 STD grafts were implanted into femoral and carotid arteries to assess patency and endothelialization at 4 and 18 weeks.
Results:
There was no significant difference in the GPAI of the HP and STD grafts at either the carotid (HP = 31.5 +/- 9.7, STD = 30.6 +/- 11.8; p > 0.05) or femoral (HP = 34.0 +/- 5.0, STD = 31.5 +/- 7.9; p > 0.05) positions. Combined data (carotid and femoral HP vs. carotid and femoral STD) also did not demonstrate a difference in GPAI (HP = 32.8 +/- 7.5, STD = 31.1 +/- 9.6; p > 0.05). Patency rates were the same at 4 weeks (75%), but greater in the HP grafts at 18 weeks (HP = 75%, STD = 37%; p > 0.05). No difference was noted in the percentage of graft endothelialization at 4 weeks (HP = 5.2 +/- 5.8, STD = 5.0 +/- 4.0; p > 0.05), however, at 18 weeks the HP graft had significantly more endothelial coverage compared to STD grafts (HP = 75.2 +/- 13.9, STD = 22.6 +/- 9.5; p < 0.01).
Conclusions:
Given that HP PTFE is no more thrombogenic than STD PTFE, and that it provides superior endothelialization, HP grafts should continue to be developed and studied for potential clinical use.