Does air plethysmography correlate with duplex scanning in patients with chronic venous insufficiency?
Related Experiment Video
Updated: Oct 23, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
P S van Bemmelen1, M A Mattos, K J Hodgson
1Department of Surgery, Southern Illinois University School of Medicine, Springfield 62794-9230.
Purpose:
Duplex ultrasonography with distal cuff deflation was used to determine the presence and size of incompetent veins and compare the results with those of air plethysmography in patients with chronic venous insufficiency.
Methods:
Thirty-two legs underwent a detailed study with both modalities. Sixteen legs had venous ulceration, six had stasis dermatitis, and ten had symptomatic varicose veins without skin changes.
Results:
Although the venous filling index (VFI) in limbs with ulcers (5.4 +/- 3.8 ml/sec) and dermatitis (7.7 +/- 4.6 ml/sec) was significantly higher (p < 0.05) than it was in limbs with varicose veins (2.6 +/- 1.7 ml/sec), there was a large amount of overlap. Only 13% of ulcerated legs had VFI greater than 10 ml/sec. Sixty-three percent of legs with ulcers, 33% of legs with dermatitis, and 90% of legs with varicose veins had VFIs less than 5 ml/sec. Mean ejection fractions (EFs) in the three groups were similar, ranging from 45% to 52%. Combining VFI and EF did not lessen the overlap between groups. Forty-one percent of limbs with ulcers or dermatitis had air plethysmography parameters in the normal or intermediate area (VFI < 5 ml/sec; EF > 40%), which in previous studies corresponded to an incidence of ulceration of only 2%. VFI had a significant but weak correlation (r = 0.39) with the diameter of incompetent veins at the knee and a somewhat stronger relationship (r = 0.55) with the diameter of lower leg veins. Total venous volume correlated moderately well with calf vein diameter (r = 0.75). The clinical status of the leg did not correlate with the diameters of incompetent veins at the knee or calf levels. All limbs with an obstructed outflow had EFs less than 60% and ulcers or dermatitis.
Conclusions:
We conclude that plethysmographic measurements of functional venous parameters (VFI,EF) do not discriminate well between limbs with uncomplicated varicose veins and limbs with ulcers or stasis dermatitis and that VFI correlates poorly with the presence of incompetent veins and their diameters. Both duplex scanning and plethysmography seem to be necessary for a complete evaluation of limbs with chronic venous insufficiency.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies