MR mammographic localization. Work in progress

K Hussman1, R Renslo, J J Phillips

  • 1Department of Radiology, Harbor-University of California, Los Angeles Medical Center, Torrance.

Radiology
|December 1, 1993
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Cases of Successful Version, with Living Children, after Failure of the Forceps.

Atlanta medical and surgical journal·2022
Same author

Reference Protocol to Assess Analytical Performance of Higher Order Structural Analysis Measurements: Results from an Interlaboratory Comparison.

Analytical chemistry·2021
Same author

The Incidence of Occult Malignancy Encountered During Uterine Surgery for Benign Indications.

Journal of minimally invasive gynecology·2016
Same author

Ising Model Reprogramming of a Repeat Protein's Equilibrium Unfolding Pathway.

Journal of molecular biology·2016
Same author

Cross Sections for the Exclusive Photon Electroproduction on the Proton and Generalized Parton Distributions.

Physical review letters·2015
Same author

Pro-angiogenic cellular and genomic expression patterns within glioblastoma influences dynamic susceptibility weighted perfusion MRI.

Clinical radiology·2015
Same journal

Noncontrast Abbreviated MRI for Post-TACE Treatment Response Monitoring of Hepatocellular Carcinoma Based on Ancillary Features from LI-RADS.

Radiology·2026
Same journal

Response Evaluation Criteria in Bone Metastases: Performance and Association of Response Classifications with Survival Outcomes.

Radiology·2026
Same journal

Entropy for Prediction of MACEs in Myocarditis: A Cardiac MRI-based Biomarker of Myocardial Tissue Heterogeneity.

Radiology·2026
Same journal

AI for Radiology: A Primer Part II. Interacting with AI Results.

Radiology·2026
Same journal

Hyperdense Capsule Sign at Noncontrast CT as an Indication for Middle Meningeal Artery Embolization for Nonacute Subdural Hematomas: A MAGIC-MT Trial Post Hoc Analysis.

Radiology·2026
Same journal

Sawtooth Cardiomyopathy: The Tiger Heart.

Radiology·2026
See all related articles

This study tested a new stereotactic device for breast lesion biopsies. Phantom tests show it offers simple, rapid, and accurate needle placement for magnetic resonance mammography.

Area of Science:

  • Medical Imaging
  • Surgical Technology
  • Oncology

Background:

  • Accurate localization of breast lesions is crucial for effective biopsy and treatment.
  • Contrast-enhanced magnetic resonance (MR) mammography improves lesion detection but requires precise guidance for biopsy.
  • Existing localization methods can be complex or time-consuming.

Purpose of the Study:

  • To evaluate the performance of a prototype stereotactic device designed for MR-guided breast lesion biopsy.
  • To assess the mechanical accuracy and feasibility of the device in a phantom setting.

Main Methods:

  • Phantom testing of a novel stereotactic device for magnetic resonance (MR) mammography.
  • Evaluation of the device's capability for simple, rapid, and accurate needle biopsy and localization.

Related Experiment Videos

  • Measurement of the mechanical accuracy of the prototype MR breast localizer.
  • Main Results:

    • The prototype stereotactic device demonstrated potential for simple, rapid, and accurate breast lesion biopsy.
    • Phantom test results indicated a mechanical accuracy of approximately plus or minus 3.5 mm at 5 cm for the MR breast localizer.

    Conclusions:

    • The tested stereotactic device shows promise for improving MR-guided breast biopsy procedures.
    • Further clinical validation is warranted to confirm the accuracy and efficacy of this MR breast localizer.