The performance of two intensive care humidifiers at high gas flows
D A Harrison1, D P Breen, N D Harris
1University Department of Anaesthetics, Queens Medical Centre, Nottingham.
Abstract:
High continuous flow breathing systems are now available to provide fresh gas flows well in excess of 100 l.min-1 in continuous positive airway pressure systems used for respiratory support. The performance of two commonly used intensive care humidifiers, the Kendal Conchatherm and the Fisher and Paykel FP310 have been assessed at flows of 50, 75, 100, 125 and 150 l.min-1. Their performance when using two humidifiers connected in parallel and in series was also studied. At a fresh gas flow of 100 l.min-1 the single Conchatherm gave an absolute water vapour concentration of 15.6 g.m-3 and the single FP310 11.9 g.m-3. At all flows the best results were achieved using two Conchaterm humidifiers in series. It is concluded that with high continuous flow breathing systems the humidification achieved with conventional humidifiers may be inadequate and it may be necessary to combine two humidifiers to obtain clinically useful humidification.
More Related Videos
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...