Related Experiment Video
Updated: Aug 20, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Formaldehyde, sodium hypochlorite, and metabisulphite are equally effective as sterilants for central delivery
A Besarab1, T DeLucia, N Picarello
1Department of Medicine, Thomas Jefferson College of Medicine, Thomas Jefferson University, Philadelphia, PA 19107.
Abstract:
Sterilants are used to disinfect reverse osmosis (RO) thin film composite membranes or peripheral loop water delivery systems. Formaldehyde (4.0% weight/volume) and metabisulphite (1.0%) were used to sterilize the RO and peripheral loop, and sodium hypochlorite (0.5%) was used to sterilize the peripheral loop with only acid/alkaline treatment of the RO; each sterilant was evaluated for 4 months. Sanitization at the machine was with sodium hypochlorite or glutaraldehyde. Quantitative RO processed water (weekly) and dialysate (4-6 from each station during the period of each sterilant) cultures were obtained. AAMI standards were used (< 200 CFU/ml RO water; < 2,000 CFU/ml dialysate). Bacterial growth exceeded Association for the Advancement of Medical Instrumentation (AAMI) limits in 16% of RO water and 4.7% of dialysate samples, but repeat cultures invariably failed to confirm initial abnormal results. Chi-square analysis showed no differences among sterilants. No difference among sterilants was noted in arithmetic or log10 mean colony counts. Sporadic low level gram positive and gram negative organism growth occurred with all sterilants. Continued "sterility" that met AAMI standards was obtained for 1 year, first with metabisulphite and then with acid/alkaline RO and sodium hypochlorite loop treatment. It is concluded that all three sterilants are effective for disinfection of hemodialysis delivery systems. Sodium hypochlorite is recommended because of its safety advantages and readily available test of adequate removal.
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control