Related Experiment Video
Updated: Aug 11, 2026

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Precision of suture placement with microscope- and loupe-assisted anastomoses
M D Rooks1, J Slappey, K Zusmanis
1Department of Orthopaedics, Emory University School of Medicine, Atlanta, GA.
Abstract:
Twenty-eight anastomoses involving seven surgeons were done on 2 mm Gortex vascular prostheses to test the effect of magnification on the precision of suture placement. One-half were done with 3.5-4x prism loupe magnification and the other one-half with 8-30x microscope magnification. The variability of suture placement (defined here as precision) was measured in a blinded fashion. The mean suture puncture to prosthesis edge measurement for the microscope-assisted group was approximately 0.03 mm closer to the edge. The variability from the mean for the microscope-assisted group was approximately 0.01 mm less than that for the loupe-assisted group. This difference was statistically significant at a P value of 0.0123.