Estimation of urinary aldosterone using thin-layer chromatography and fluorimetry
D Mattingly1, H Martin, C M Tyler
1Postgraduate Medical School, University of Exeter.
Journal of Clinical Pathology
|December 1, 1993
Summary
This study developed a new fluorimetric method for measuring urinary aldosterone. Overnight urine samples are as effective as 24-hour collections for diagnosing hyperaldosteronism.
Area of Science:
- Biochemistry
- Clinical Chemistry
- Endocrinology
Background:
- Aldosterone is a key hormone in regulating blood pressure and electrolyte balance.
- Accurate measurement of urinary aldosterone is crucial for diagnosing conditions like hyperaldosteronism.
Purpose of the Study:
- To develop and validate a fluorimetric assay for urinary aldosterone.
- To establish reference ranges for 24-hour and overnight urine samples.
- To evaluate the utility of overnight urine samples for detecting hyperaldosteronism.
Main Methods:
- Hydrolysis of aldosterone conjugates followed by oxidation.
- Thin-layer chromatography on silica gel.
- Fluorescence detection using sulfuric acid on the chromatogram.
Main Results:
- A linear correlation was observed between aldosterone levels and chromatogram peak area.
- The method demonstrated good intra-assay (4.4%) and inter-assay (6.8%) precision.
- Mean aldosterone excretion was 15.7 nmol/24 hours and 2.6 nmol/8 hours (overnight).
- Elevated aldosterone levels were detected in patients with primary and secondary aldosteronism.
Conclusions:
- The developed fluorimetric technique offers an accurate method for urinary aldosterone assay.
- Overnight urine collections are a viable and effective alternative to 24-hour collections for diagnosing hyperaldosteronism.