Related Experiment Videos
Open half-pin insertion for distal radial fractures
1Department of Surgery, University of Maryland Hospital, Baltimore 21201.
Military Medicine
|November 1, 1993
Summary
The open technique for external fixation of distal radial fractures showed efficacy, with most patients experiencing no major complications. This method reduced risks associated with pin insertion for unstable fractures.
Area of Science:
- Orthopedics
- Trauma Surgery
- Biomedical Engineering
Background:
- Unstable distal radial fractures pose significant treatment challenges.
- External fixation is a common treatment, but pin-tract complications can occur.
- The open technique for pin insertion aims to mitigate these complications.
Purpose of the Study:
- To evaluate the efficacy and safety of the open technique for half-pin insertion in external fixation for unstable distal radial fractures.
- To assess the incidence of pin-tract complications and other adverse events.
- To determine functional outcomes, including wrist range of motion and grip strength.
Main Methods:
- A prospective study involving 22 patients with unstable distal radial fractures.
- External fixation with half-pin insertion using the open technique.
- Follow-up included assessment of pin sites, complications, wrist range of motion, and grip strength at an average of 8 months.
Main Results:
- Of 19 patients, 7 (37%) had early pin-tract drainage, which resolved within 2 weeks.
- No instances of pin loosening, breakage, infection, nerve entrapment, or tendon injury were reported.
- Average wrist flexion/extension was 51/47 degrees, with grip strength at 61% of the uninjured side.
Conclusions:
- The open technique for half-pin insertion in external fixation is efficacious for unstable distal radial fractures.
- This method demonstrates a low complication rate, including minimal pin-tract issues.
- Functional outcomes suggest good recovery of wrist motion and grip strength.