Related Experiment Video
Updated: Oct 13, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Measurement of oxygen consumption and arterial-venous oxygen saturation following total artificial heart implantation
P D Robison1, G M Pantalos, J W Long
1Artificial Heart Research Laboratory, University of Utah, Salt Lake City.
Abstract:
Current algorithms for control of the total artificial heart are directed at maintaining hemodynamic homeostasis. Future control systems will also need to modify cardiac output in response to metabolic needs. This study was undertaken to evaluate oxygen metabolism monitoring as an indicator of the adequacy of organ and tissue perfusion. Following recovery from implantation of the Utah-100 pneumatic total artificial hearts, five calves (85 to 95 kg) underwent placement of fiberoptic oximetry catheters to determine mixed venous and arterial oxygen saturations. By continuously measuring oxygen consumption with a gas analyzer, oxygen utilization and delivery were determined. In the awake calves, at-rest cardiac output was varied to produce hyperperfused and hypoperfused conditions while the adequacy of tissue perfusion was assessed with continuous mixed venous oximetry and confirmed with serum lactate (Lact) levels. Inadequate tissue perfusion (Lact > 1.0 mmol/L) was evidenced by a mixed venous oxygen saturation < 40%, oxygen delivery of < 200.0 milliliters/minute/m2), and oxygen delivery to utilization ratio of < 1.8 during the hypoperfusion conditions of the experiment. By accounting for oxygen consumption, the ratio of oxygen delivery to oxygen utilization was predictive of the adequacy of tissue perfusion. These results suggest that continuous oxygen metabolism monitoring may be useful as a physiologic control modifier to maintain total artificial heart output sufficient to meet physiologic needs, while avoiding hyperperfusion, unnecessary wear and deterioration of the implanted device due to excessive heart rates.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:28Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...