Related Experiment Video
Updated: Aug 9, 2026

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Comparison of personnel radiation dosimetry from myocardial perfusion scintigraphy: technetium-99m-sestamibi versus
1Nuclear Medicine Department, William Beaumont Hospital, Royal Oak, MI 48073-6769.
Abstract:
The whole-body and hand radiation doses to our technical staff were retrospectively compared for three distinct 4-mo periods when either 201TI or 99mTc-sestamibi were exclusively used for stress myocardial perfusion imaging. During the initial 4-mo period when 99mTc-sestamibi replaced 201TI, the mean whole-body film badge readings increased from 100 to 450 microSv/mo (p < 0.001) for nuclear medicine technologists (n = 10) and from 240 to 560 microSv/mo (p < 0.05) for radiopharmacy technologists (n = 2). Mean TLD readings to the hands also increased, although the differences were not statistically significant for the nuclear medicine technologists. Noninvasive cardiology staff were monitored with film badges and the mean whole-body film badge reading, when 99mTc-sestamibi was the imaging agent, was 360 microSv per month. Radiation reduction methods that decreased radiation exposure to staff were utilized. The most effective included the use of a lead face shield and lead lined storage container in the noninvasive imaging area, handling spills by shielding instead of decontamination and methods to reduce time spent in close proximity to the patient.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT

