Validation and reproducibility of pressure-corrected aortic distensibility measurements using pulse-wave-velocity
E D Lehmann1, J R Parker, K D Hopkins
1Division of Radiological Sciences, UMDS, St Thomas's Hospital, London, England.
Abstract:
A non-invasive Doppler ultrasound technique is described for the assessment of aortic compliance based on the in vivo measurement of pulse wave velocity along the thoraco-abdominal aortic pathway. A structured protocol, which has been developed to improve the reproducibility of the technique, is validated. A method of correcting for the effect of non-chronic changes in blood pressure on arterial elasticity is considered and applied to compliance measurements performed on 66 normal, healthy volunteers. The results of a study to ascertain the overall reproducibility of the method are provided and problems associated with the technique are discussed. Medical disorders such as atherosclerosis, diabetes mellitus, familial hypercholesterolaemia and growth hormone deficiency have all been shown to affect arterial wall compliance. It is suggested that the in vivo measurement of pressure-corrected aortic distensibility may be a useful, non-invasive tool for assessing such patients' susceptibility to atheromatous arterial disease and for monitoring their response to therapy. Measurements in the aorta may be especially pertinent since the natural history of fatty streaks there tends to parallel that in coronary arteries thereby potentially affording a convenient surrogate estimate of coronary heart disease.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.