Serum vanadium levels in chronic hemodialysis patients
Related Experiment Video
Updated: Oct 20, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
1Utano National Hospital, Kyoto, Japan.
Abstract:
Serum vanadium, aluminum, silicon and beta 2-microglobulin levels as well as the red cell count, hemoglobin and systolic blood pressure were simultaneously measured in 80 chronic hemodialysis patients. The serum vanadium level was positively correlated with the serum levels of aluminum, silicon and beta 2-microglobulin as well as the systolic blood pressure, and was inversely correlated with the red cell count and hemoglobin. The mean serum vanadium level was 18.4 +/- 7.6 ng/ml before hemodialysis and decreased to 13.0 +/- 5.30 ng/ml at the completion of dialysis. The dialysate vanadium level increased from 0.4 +/- 0.2 (inflow) to 1.0 +/- 0.4 ng/ml (outflow). It was concluded that vanadium was transferred from blood to dialysate when purified water was used in the preparation of the dialysate.
Related Concept Videos
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.