Somatosensory evoked potentials after iohexol myelography
J G Imanse1, D M Laman, H van Duijn
1Department of Clinical Neurophysiology, St. Lucas Hospital, Amsterdam, The Netherlands.
Clinical Neurology and Neurosurgery
|June 1, 1993
Summary
Iohexol lumbar myelography did not significantly alter tibial nerve somatosensory evoked potentials (SSEPs), indicating a low neurotoxic profile for this contrast agent. Lumbar puncture alone also showed no effect on SSEP measurements.
Area of Science:
- Neuroscience
- Radiology
- Clinical Electrophysiology
Background:
- Iohexol is a widely used non-ionic, low-osmolar contrast medium for lumbar myelography.
- Assessing the neurotoxicity of contrast agents is crucial for patient safety during neuroradiological procedures.
- Somatosensory evoked potentials (SSEPs) are a sensitive electrophysiological technique for evaluating the integrity of the somatosensory nervous system.
Purpose of the Study:
- To evaluate the potential neurotoxic effects of iohexol lumbar myelography on the tibial nerve and S1 dermatome.
- To establish the safety profile of iohexol as a contrast agent in the context of electrophysiological monitoring.
Main Methods:
- Tibial nerve and S1 dermatome somatosensory evoked potentials (SSEPs) were recorded in patients before and after iohexol lumbar myelography.
- A control group underwent lumbar puncture (LP) without contrast injection, with SSEPs recorded before and after the procedure.
- Analysis focused on changes in SSEP latencies and amplitudes to detect neurotoxic effects.
Main Results:
- No statistically significant changes in SSEP latencies or amplitudes were observed following iohexol lumbar myelography.
- The control group, undergoing LP without contrast, also demonstrated no significant alterations in SSEP components.
- These findings suggest that neither iohexol nor the lumbar puncture procedure itself adversely affects SSEP measurements.
Conclusions:
- Iohexol exhibits a low neurotoxic profile when used for lumbar myelography, as evidenced by stable SSEP findings.
- Lumbar puncture as a procedure does not interfere with the electrophysiological assessment using SSEPs.
- The study supports the safe use of iohexol in patients undergoing myelography and SSEP evaluation.