Urinary glucose testing by diabetic patients

G M Shenfield, J M Steel

    The Practitioner
    |January 1, 1977
    PubMed
    Summary
    This summary is machine-generated.

    Diabetic patients often make errors when testing urine with Clinitest tablets, primarily due to issues with dropper use and timing. Improved initial patient instruction is recommended to enhance testing accuracy.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The effect of different nebulizers with and without intermittent positive pressure breathing on the absorption and metabolism of salbutamol.

    British journal of clinical pharmacology·2012
    Same author

    The clinical pharmacology of salmefamol.

    British journal of clinical pharmacology·2012
    Same author

    The effect of prednisone treatment on the half-life of intravenous hydrocortisone.

    British journal of clinical pharmacology·2012
    Same author

    Absorption of drugs by the lung.

    British journal of clinical pharmacology·2012
    Same author

    Failure to weigh patients in hospital: a medication safety risk.

    Internal medicine journal·2007
    Same author

    An assessment of the adequacy of suspension of insulin in pen injectors.

    Diabetic medicine : a journal of the British Diabetic Association·2004
    Same journal

    Improving pain control in diabetic neuropathy.

    The Practitioner·2017
    Same journal

    Tailor management to the patient with fibroids.

    The Practitioner·2017
    Same journal

    Preventing stroke and assessing risk in women.

    The Practitioner·2017
    Same journal

    Depression in adults linked to maltreatment in childhood.

    The Practitioner·2017
    Same journal

    Early referral improves long-term outcomes in rheumatoid arthritis.

    The Practitioner·2017
    Same journal

    Diagnosing and managing mild cognitive impairment.

    The Practitioner·2017
    See all related articles

    Area of Science:

    • Diabetes Management
    • Clinical Chemistry
    • Patient Education

    Background:

    • Accurate urine glucose monitoring is crucial for effective diabetes management.
    • The Clinitest tablet method is a common point-of-care diagnostic tool for urine glucose assessment.
    • Patient technique can significantly impact the reliability of diagnostic tests.

    Purpose of the Study:

    • To evaluate the accuracy of urine glucose testing using Clinitest tablets among diabetic patients.
    • To identify common errors made by patients during the Clinitest procedure.
    • To recommend improvements in patient education for urine glucose testing.

    Main Methods:

    • Observational study involving 100 diabetic patients performing urine glucose tests with Clinitest tablets.

    Related Experiment Videos

  • Systematic recording of errors related to procedural steps, including dropper usage and timing.
  • Analysis of error patterns to determine the most frequent mistakes.
  • Main Results:

    • Only 20% of the 100 diabetic patients demonstrated correct technique without errors.
    • The primary sources of error were identified as incorrect use of the dropper and improper timing.
    • A significant majority of patients exhibited deficiencies in performing the test accurately.

    Conclusions:

    • Current patient instruction for Clinitest tablet use is insufficient to ensure accurate results.
    • Enhanced and more detailed initial training on dropper handling and timing is essential for diabetic patients.
    • Improving patient technique through better education can lead to more reliable self-monitoring of diabetes.