Jove
Visualize
Contact Us

Related Experiment Videos

Positioning for knee strengthening exercises

D P Currier

    Physical Therapy
    |February 1, 1977
    PubMed
    Summary
    This summary is machine-generated.

    Maximal isometric knee extensor force is significantly greater when the hip is at 110 degrees or more, compared to 100 degrees. Exercise equipment design should accommodate varying hip angles for optimal muscle engagement.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Effects of electrical and electromagnetic stimulation after anterior cruciate ligament reconstruction.

    The Journal of orthopaedic and sports physical therapy·1993
    Same author

    Effect of variation in the burst and carrier frequency modes of neuromuscular electrical stimulation on pain perception of healthy subjects.

    Physical therapy·1992
    Same author

    Effect of motor neuromuscular electrical stimulation on microvascular perfusion of stimulated rat skeletal muscle.

    Physical therapy·1991
    Same author

    Electrophysiologic responses of human sural nerve to temperature.

    Physical therapy·1989
    Same author

    Comparison of selected pulse frequencies from two different electrical stimulators on blood flow in healthy subjects.

    Physical therapy·1988
    Same author

    Effects of high voltage pulsed electrical stimulation on blood flow.

    Physical therapy·1988
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies

    Area of Science:

    • Biomechanics
    • Exercise Physiology

    Background:

    • Understanding the biomechanics of muscle contraction is crucial for optimizing exercise equipment design.
    • Previous research has not fully explored the impact of hip joint angles on knee extensor strength during isometric contractions.

    Purpose of the Study:

    • To investigate the effect of different hip joint angles on maximal isometric knee extensor muscle force in healthy adults.
    • To provide data that can inform the design of exercise machines for improved efficacy and user accommodation.

    Main Methods:

    • Fifty healthy subjects (20 males, 30 females) performed maximal isometric contractions of the right knee extensors.
    • Hip angles were set at 100, 110, 120, and 130 degrees relative to the horizontal, with the knee in 60 degrees of flexion.
    • Knee extensor force was measured at each hip angle.

    Related Experiment Videos

    Main Results:

    • Knee extensor force was significantly higher at hip angles of 110, 120, and 130 degrees compared to 100 degrees.
    • No significant differences in force were observed between hip angles of 110, 120, and 130 degrees.
    • Results were consistent across both male and female participants.

    Conclusions:

    • Hip joint positioning significantly influences maximal isometric knee extensor strength.
    • Current exercise unit designs may not optimize muscle activation due to fixed hip angles.
    • Recommendations for exercise equipment include adjustable hip positioning for back stabilization and a narrower frame for better user accessibility.