Related Experiment Videos
Infragenicular in situ vein bypass graft occlusion: a multivariate risk factor analysis
K Varty1, N J London, J A Brennan
1Department of Surgery, University of Leicester, Leicester Royal Infirmary, U.K.
Abstract:
Early postoperative thrombosis and the later development of graft stenoses are the two major causes of vein bypass graft failure. The risk factors for both these outcomes were analysed in a multivariate analysis of 82 consecutive infragenicular in situ vein grafts. Twenty-four grafts failed within 30 days but eight were successfully revised. Technical errors accounted for six of the failures. A multivariate analysis revealed graft resistance > 1.4 peripheral resistance units (odds ratio 5.8, 95% C.I. 1.6-20) as the only independent risk factor for early graft failure. Eighteen grafts (27%) developed a stenosis most commonly in the distal third of the graft (46%). Poor quality, small diameter vein was the only independent risk factor for graft stenosis (odds ratio 7, 95% C.I. 1.5-34). Composite vein grafts, where narrowed and thickened vein had been replaced, had a significantly lower stenosis rate (difference in proportions 0.41, 95% C.I. 0.1-0.8, Mann-Whitney U test).