Related Experiment Video
Updated: Aug 12, 2026

Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Comparison of rectal and axillary temperatures in neonates admitted to a neonatal unit
1Department of Pediatrics, St. John's Medical College and Hospital, Bangalore.
To determine whether axillary temperature could be used as an alternative to rectal temperature, 45 neonates were subjected to simultaneous rectal temperature and axillary temperature recordings. Each baby had an average of 10 recordings over the first 72 hours. The mean of these readings was taken and subjected to regression analysis and the 't' paired test. The overall mean difference between the rectal and axillary temperature was 0.3 degrees F. The mean difference was least in preterm small for date (SFD) babies (0.2 degrees F) and most in preterm appropriate for date (AFD) babies (0.5 degrees F). The mean difference was less in incubator babies (0.2 degrees F) compared to those in warmer cradles (0.4 degrees F). The regression analysis showed that the correlation was good in all groups except the term small for date babies. We conclude that axillary temperature could be used as an alternative to rectal temperature in neonates.
To determine whether axillary temperature could be used as an alternative to rectal temperature, 45 neonates were subjected to simultaneous rectal temperature and axillary temperature recordings. Each baby had an average of 10 recordings over the first 72 hours. The mean of these readings was taken and subjected to regression analysis and the 't' paired test. The overall mean difference between the rectal and axillary temperature was 0.3 degrees F. The mean difference was least in preterm small for date (SFD) babies (0.2 degrees F) and most in preterm appropriate for date (AFD) babies (0.5 degrees F). The mean difference was less in incubator babies (0.2 degrees F) compared to those in warmer cradles (0.4 degrees F). The regression analysis showed that the correlation was good in all groups except the term small for date babies. We conclude that axillary temperature could be used as an alternative to rectal temperature in neonates.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...