Attenuation correction using count-limited transmission data in positron emission tomography

S R Meikle1, M Dahlbom, S R Cherry

  • 1Department of Nuclear Medicine, Royal Prince Alfred Hospital, Sydney, Australia.

Journal of Nuclear Medicine : Official Publication, Society of Nuclear Medicine
|January 1, 1993
PubMed
Summary

Processing transmission data in Positron Emission Tomography (PET) affects image accuracy. New methods allow accurate PET attenuation correction with shorter scan times, reducing noise and improving quantitative accuracy.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A high resolution and high detection efficiency depth-encoding detector for brain positron emission tomography based on a 0.75 mm pitch scintillator array.

Journal of instrumentation : an IOP and SISSA journal·2021
Same author

Tomographic imaging with Compton PET modules: ideal case and first implementation.

Journal of instrumentation : an IOP and SISSA journal·2021
Same author

Lead-free MCP to improve coincidence time resolution and reduce MCP direct interactions.

Physics in medicine and biology·2021
Same author

Denoising non-steady state dynamic PET data using a feed-forward neural network.

Physics in medicine and biology·2020
Same author

A 6-month randomized, double-blind, placebo-controlled trial of weekly exenatide in adolescents with obesity.

Pediatric obesity·2020
Same author

SU-E-I-82: Image Signal-To-Noise Equalization in Whole Body PET Using Variable Acquisition Times.

Medical physics·2017

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Image Processing

Background:

  • Poisson noise in transmission data significantly impacts Positron Emission Tomography (PET) measurements, especially at low count rates.
  • Existing transmission data processing methods can introduce spatial resolution differences, affecting quantitative accuracy and causing image artifacts.

Purpose of the Study:

  • To investigate the impact of transmission data processing on noise and quantitative accuracy in reconstructed PET images.
  • To develop improved strategies for processing count-limited transmission data to enhance accuracy and reduce scan times.

Main Methods:

  • Analysis of the effects of transmission data smoothing on spatial resolution and quantitative accuracy.
  • Development of improved strategies for processing count-limited transmission data, including image segmentation for attenuation correction.

Related Experiment Videos

Main Results:

  • Differences in spatial resolution between emission and transmission scans negatively influence quantitative accuracy and can create artifacts.
  • Current noise suppression techniques are insufficient for significantly reducing transmission scan times.
  • A novel method using segmentation of attenuation images enables accurate attenuation correction with transmission scan times as low as 2 minutes, without increasing image noise.

Conclusions:

  • Standard transmission data processing in PET can compromise image quality and accuracy.
  • Improved processing strategies, particularly those involving image segmentation, are crucial for efficient and accurate PET imaging.
  • The developed method allows for significantly reduced transmission scan times, enhancing the practicality of PET scans without sacrificing image quality.