Gastric Point of Care Ultrasound in Adults: Image Acquisition and Interpretation
Published on: September 22, 2023
Real time ultrasonography of the gastric antrum
R Ricci1, I Bontempo, E Corazziari
1Cattedra di Gastroenterologia I, Università La Sapienza, Roma, Italy.
Abstract:
This study aimed to evaluate whether serial ultrasound measurements of antral volumes are reproducible and, if so, whether they are representative of the entire gastric contents and reliably measure gastric emptying. The antral volume was measured in man after oral and intragastric administration of known amounts of 5% glucose solutions, and on two separate occasions in the same subjects, after the ingestion of a standardised solid-liquid meal (1050 kcal). Antral volume measurements were performed in both supine and upright positions; inter- and intraobserver measurement errors were also assessed. After ingestion or intragastric administration of equal amounts of liquid, antral volumes determined by ultrasound showed a wide intersubject variability. In each individual subject, however, a linear trend was found between the antral volume and amount of ingested or administered liquid. Intrasubject variability of antral volume measurements was at its minimum in fasting conditions and 300 minutes after ingestion of the solid-liquid meal. Intra- and interobserver variations and whether the patient was erect or supine did not affect measurements of antral volumes. These results support the use of real time ultrasound in determining the gastric emptying time. Results at fasting and 300 minutes after a solid-liquid meal are stable end points of measurement.
More Related Videos
08:22The Application of Point-of-Care Ultrasonography (POCUS) in the Management of Acute Respiratory Distress Syndrome (ARDS) in the Intensive Care Unit
Published on: December 12, 2025
07:34Ultrasonography-Guided Nasogastric Tube Placement and Verification: A Standardized Nursing Protocol
Published on: April 7, 2026
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography