Related Experiment Video
Updated: Jul 3, 2026

A New Murine Model of Endovascular Aortic Aneurysm Repair
Published on: July 7, 2013
Routine invasive hemodynamic monitoring does not increase risk of aortic graft infection
P Raphael1, T H Cogbill, E L Dunn
1Department of Surgery, Methodist Medical Center, Dallas, Texas.
Objective:
To determine whether invasive hemodynamic monitoring resulted in an increased rate of aortic graft infection.
Design:
Retrospective review with establishment of late follow-up.
Setting:
Two referral teaching community medical centers.
Patients:
Three hundred thirty consecutive patients who underwent elective aortoiliac (174), aortofemoral (91), or aortic tube (65) prosthetic graft placements during a 6-year period at the two institutions. All patients had percutaneous pulmonary artery catheter and radial artery cannula placement before surgery. Monitoring catheters were routinely removed within 72 hours.
Outcome Measures:
Early and late complications of catheter placement, perioperative morbidity and mortality, and late graft-related complications.
Results:
Eighteen (5%) patients died in the perioperative period. Less than 2-year follow-up was possible in 67 patients. The remaining 245 patients were observed from 2 to 9 years (mean, 4.4 years). Graft infection was not identified in any patient.
Conclusion:
Routine invasive hemodynamic monitoring was not associated with an increase in the rate of prosthetic aortic graft infection.