Concurrent percutaneous balloon valvotomy for combined rheumatic tricuspid and aortic stenosis
S Shrivastava1, K C Goswami, V Dev
1All India Institute of Medical Sciences, Ansari Nagar, New Delhi.
Abstract:
Concurrent percutaneous balloon valvotomy of aortic and tricuspid valve was successfully performed in a 20-year-old male with severe rheumatic aortic and tricuspid stenosis. Balloon valvotomy was done using a 18-mm single balloon for aortic and 20 + 20-mm double balloon for the tricuspid valve. Immediately after valvotomy the peak transaortic systolic gradient decreased from 120 to 32 mmHg and the aortic valve area increased from 0.27 to 1.1 cm2, the mean and end-diastolic trans-tricuspid gradient decreased from 14 and 18 to 1.5 and 2 mmHg, respectively, the tricuspid valve area increased from 0.8 to 3.6 cm2 and the cardiac-index increased from 2 to 2.9 l/mt/m2. At 1 year of follow-up the clinical (NYHA class 1) and hemodynamic improvement was maintained.
More Related Videos
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Regurgitation III: Medical Management
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management