Endoscopic ACL reconstruction: a technical note on tunnel length for interference fixation

B Kenna1, T M Simon, D W Jackson

  • 1Southern California Center for Sports Medicine, Long Beach.

Arthroscopy : the Journal of Arthroscopic & Related Surgery : Official Publication of the Arthroscopy Association of North America and the International Arthroscopy Association
|January 1, 1993
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Shinsplints:An Update.

The Physician and sportsmedicine·2016
Same author

Iliotibial Band Syndrome in Distance Runners.

The Physician and sportsmedicine·2016
Same author

Athletic Injuries to the Knee: Evaluation Using Magnetic Resonance Imaging.

The Physician and sportsmedicine·2016
Same author

Perplexities of pertussis: recent global epidemiological trends and their potential causes.

Epidemiology and infection·2013
Same author

2009 Melbourne metropolitan sewerage strategy: a portfolio of decentralised and on-site concept designs.

Water science and technology : a journal of the International Association on Water Pollution Research·2010
Same author

Experiments in long-distance holographic imagery.

Applied optics·2010

Bone-patella tendon-bone autograft length varies, potentially causing issues with tibial tunnel fixation. A simple calculation and intraoperative check help estimate required tunnel length, allowing adjustments to prevent graft protrusion.

Area of Science:

  • Orthopedic surgery
  • Biomechanical engineering

Background:

  • Bone-patella tendon-bone (BPTB) autografts are commonly used in anterior cruciate ligament (ACL) reconstruction.
  • Graft length variability can lead to intraoperative complications, such as interference screw fixation failure.
  • Accurate graft sizing is crucial for successful tunnel preparation and fixation.

Purpose of the Study:

  • To present a method for estimating the required tibial tunnel length for BPTB autografts.
  • To provide guidance on intraoperative adjustments to ensure proper graft fit and fixation.

Main Methods:

  • A calculation to estimate the necessary tibial tunnel length based on graft dimensions.
  • Intraoperative measurement using a calibrated drill to confirm tunnel accommodation.
  • Techniques for graft adjustment, including bone plug trimming and tunnel deepening.

Related Experiment Videos

Main Results:

  • A straightforward calculation can predict the tibial tunnel length needed for BPTB autografts.
  • Intraoperative measurements confirm the adequacy of the prepared tunnel.
  • Adjustments can be made to prevent graft protrusion and ensure secure fixation.

Conclusions:

  • Preoperative estimation and intraoperative verification of tibial tunnel length are essential for BPTB autografts.
  • Simple adjustments can resolve issues of graft over-length, optimizing fixation.
  • This approach facilitates successful ACL reconstruction with BPTB grafts.