Impaired subsidiary pacemaker function in patients with a right bundle branch block created prior to complete
G Kreiner1, G Heinz, P Siostrzonek
12nd Department of Medicine/Cardiology, University of Vienna, Austria.
Abstract:
The impact of a right bundle branch block (RBBB), inadvertently created prior to complete ablation of the atrioventricular (AV) junction, on the intrinsic subsidiary pacemaker function was investigated. In 31 patients suffering from intractable supraventricular tachyarrhythmia, catheter ablation of the AV junction was performed using direct current (n = 13) or radiofrequency (n = 18) energy. In 16/31 patients a RBBB was created prior to complete AV ablation. Subsidiary pacemaker function was evaluated after a mean period of 5 months. Following 5 min of ventricular pacing (70 beats.min-1) escape interval and spontaneous heart rate were measured. In patients with a RBBB there was a trend towards a longer escape interval (2979 +/- 2559 vs 1867 +/- 1254 ms, P = ns) and a significantly lower intrinsic heart rate (38 +/- 14 vs 47 +/- 8 beats.min-1, P < 0.05). Pacemaker dependency was only observed among patients with a RBBB (4/16 vs 0/15, P < 0.05). HV intervals were shorter in those energy discharges resulting in a RBBB as compared to those inducing a complete heart block (52 +/- 8 vs 66 +/- 6 ms, P < 0.05). Creation of a RBBB prior to complete ablation of the AV junction results in impaired intrinsic subsidiary pacemaker function; the most proximal catheter position should be carefully sought to minimize the risk of pacemaker dependency.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
08:56Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
Published on: September 24, 2021
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Antiarrhythmic Drugs: Class II Agents as β-Adrenergic Blockers
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias