A standardized finger cooling test for Raynaud's phenomenon: diagnostic value and sex differences
M L Bartelink1, H Wollersheim, E Leesmans
1Department of Medicine, University Hospital Nijmegen, The Netherlands.
Abstract:
In 99 patients with primary Raynaud's phenomenon (RP), in 97 with secondary RP and in 101 healthy subjects, finger skin temperature and laser Doppler flux were measured before, during and after immersion of the hand in a 16 degrees C water bath. We determined the baseline value, the values at the end of the cooling period and after 12 and 20 min of recovery, the percentual decrease during cooling and the mean values during cooling, during recovery and during the whole test. Most of the finger skin temperature and laser Doppler flux parameters were significantly lower in females than in males in all three groups. There were no significant differences between patients with either primary or secondary RP. In both sexes, all test parameters (with the exception of the percentual decrease during cooling) were significantly lower in the patients with RP than in healthy subjects. With a diagnostic specificity of 70%, the sensitivity varied between 55% and 81% for the different test parameters. Although, in both sexes, finger skin temperature and laser Doppler flux values before, during and after cooling were significantly lower in patients with RP than in healthy subjects, the considerable overlap between both groups limits the diagnostic value in individual cases.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation