Effect of sterilization on contaminated sponges
Related Experiment Video
Updated: Nov 6, 2026

The Polyvinyl Alcohol Sponge Model Implantation
Published on: April 18, 2012
R H Kuritani1, N J McDonald, R J Sydiskis
1Baltimore College of Dental Surgery, Dental School, University of Maryland at Baltimore.
Abstract:
Sponges are routinely used as a storage medium for endodontic files during clinical practice; however, very little research has been done to determine the effectiveness of sterilization procedures for these contaminated sponges. The purpose of this in vitro study was to determine the efficacy of chemical vapor sterilizers (chemiclaves), steam pressure sterilizers (autoclaves), and dry heat sterilizers on laboratory contaminated sponges. Four different types of sponges were used in this study: a black, relatively nonporous sponge; a red, semiporous stationary sponge; a blue, endodontic sponge, and a yellow, common household sponge. Natural sponges were eliminated from the study, because their large pore size made them unsuitable as a storage medium for endodontic instruments. The sponges were divided into three groups: chemiclave, autoclave, and dry heat. Five samples of each sponge type were impregnated with biological indicating strips containing spores of Bacillus stearothermophilus. Each sponge was subjected to 25 cycles of sterilization. The spore strip indicator was inserted into the sponges at 1, 5, 10, 15, 20, and 25 cycles. The spore strip was cultivated in trypticase soy broth medium solution at 55 +/- 1 degree C for 7 days. At 7 days the culture vials were read for turbidity; its presence indicating a positive culture. The samples that were subjected to chemiclaving demonstrated positive cultures of 0.00%, 0.00%, and 30.00% and those to autoclaving 3.33%, 0.00%, and 0.00% positive cultures for the black, red, and blue sponge types, respectively. None of the sponges survived dry heat sterilization. The O-Cell-O sponges become unusable when subjected to all of the sterilization methods used in this study.
More Related Videos
14:17The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
07:28High-throughput, Robust and Highly Time-flexible Method for Surface Sterilization of Arabidopsis Seeds
Published on: October 4, 2021
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Antimicrobial Effectiveness
Methods for Controlling Microbial Growth