A feasibility study on quantitating myocardial perfusion with Albunex, an ultrasonic contrast agent
1Bioengineering Program, Pennsylvania State University, University Park 16802.
Abstract:
Quantitating regional myocardial perfusion has been the much sought-after but still elusive goal of many intensive investigations over the years. Videodensitometry of the variation of myocardial echogenicity in two-dimensional (2-D) echocardiograms as a function of time in conjunction with the injection of a bolus of an ultrasound contrast agent has been used clinically as a tool for a direct assessment of regional myocardial perfusion, despite that the precise relationship between tissue echogenicity observed on an image and the echoes detected by the ultrasonic probe is unknown. A study was undertaken to determine whether ultrasonic backscatter calculated from unprocessed radio frequency (RF) echoes returned from myocardium could be used to quantitate regional myocardium perfusion. A real-time ultrasonic scanner has been modified and interfaced to a microcomputer to acquire RF data at a rate up to 10 frames per second. Preliminary experimental data were obtained from four open-chest dogs following intracoronary injection of a bolus of Albunex and two dogs following intravenous injection with this modified scanner. On one hand, these results indicate that the integrated backscatter measured from the region of myocardium perfused by the coronary artery where Albunex is injected and selected for monitoring initially increases, reaches a peak, and then decreases as the contrast agent is washed out and that the magnitude of the peak is approximately linearly proportional to the volume concentration of Albunex microspheres injected, clearly demonstrating the feasibility of this approach for quantitating region myocardial perfusion. On the other hand, intravenous injections did not result in any appreciable change in myocardial backscatter in the left ventricle although a response could be observed in the left ventricular blood pool.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
06:46Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
Published on: July 16, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies