A portable blood gas analyzer for equine venous blood
Related Experiment Video
Updated: Nov 6, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
L A Mitten1, K W Hinchcliff, R Sams
1Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University, Columbus 43210, USA.
Abstract:
Evaluation of a portable blood gas analyzer, (StatPal II, Unifet, Inc, La Jolla, CA) was performed using tonometered solutions and equine blood. Samples were analyzed by the StatPal II and either an Instrument Laboratory IL1306 (Lexington, MA) or a Radiometer ABL50 blood gas analyzer (Radiometer America Inc., Westlake, OH). Comparison of the StatPal II and the IL1306 was done by analysis of 3 tonometered solutions (acidic, normal, and alkalotic) and 27 equine venous blood samples. Blood pH, PCO2, PO2, and [HCO3] values were altered by IV infusion of 5% sodium bicarbonate or exercising the horses on a treadmill. Comparison of the StatPal II and the Radiometer was performed by analysis of 78 blood samples collected from Standardbred horses before a race. Data were analyzed for the venous blood samples using a paired two-tailed Student's t test and Bland-Altman plots, with significance set at P < .05. The coefficients of variation for pH, Pco2, Po2, and [HCO3-] values of the tonometered solutions analyzed by the StatPal II ranged from 0.067% to 0.087%, 2% to 3.21%, 1.21% to 2.67%, and 0.267% to 0.828%, respectively. Comparison of the equine blood samples analyzed by the StatPal II and the IL1306 demonstrated statistically significant, but clinically irrelevant differences in pH, Pco2, and Po2, but not [HCO3-]. There were statistically significant, but clinically irrelevant differences between the StatPal II and the Radiometer for pH, Pco2, and [HCO3-], but not for Po2. It is concluded that the StatPal II provides reproducible and acceptable analysis of equine venous blood gas samples.
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...