Ultrasound contrast agents nucleate inertial cavitation in vitro
1Battelle Pacific Northwest Laboratories, Richland, WA, USA.
Abstract:
Some ultrasound contrast agents contain stable bodies of gas, and this study was undertaken to determine if these agents could provide nuclei for inertial cavitation. Inertial cavitation was detected and assessed by the measurement of the sonochemical hydrogen peroxide after exposure to 2.17-, 2.95- or 3.8-MHz ultrasound. A noncavitating system was obtained by removing cavitation nuclei from the rotating tube exposure chambers by vacuum degassing, and from the phosphate-buffered saline medium by filtering. Albunex added at 10-2, 10-3 or 10-4 dilutions, or Levovist added at 2 mg mL-1, 0.2 mg mL-1 or 0.02 mg mL-1 all initiated significant H2O2 production for 2.17-MHz ultrasound at 0.41 MPa or higher spatial peak pressure amplitude for 5 min exposure gated at 0.25 s on and off with 60-rpm rotation. Not rotating the tube virtually eliminated H2O2 production. For 2.5-min continuous exposure, both agents initiated significant H2O2 production for 2.95-MHz exposure at 0.58 MPa or higher, but not for 3.8-MHz exposure up to 1.16 MPa. Bubble-based ultrasound contrast agents therefore appear to be able to provide nuclei for inertial cavitation in the rotating tube exposure system.
More Related Videos
08:19Controllable Nucleation of Cavitation from Plasmonic Gold Nanoparticles for Enhancing High Intensity Focused Ultrasound Applications
Published on: October 5, 2018
06:02Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release
Published on: June 12, 2021
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...