Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

A small-volume constant-flow air sampling device for thermal desorption GC analysis

S Kanno1, M Sugimoto

  • 1National Institute of Industrial Health, Kawasaki, Japan.

Industrial Health
|January 1, 1995
PubMed
Summary

A novel glass syringe air sampler with disposable membrane filters provides constant airflow for 15 minutes. This device is effective for measuring organic solvent vapor concentrations in workplace environments.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Attachment of bacterial cells to carbon electrodes.

Bioelectrochemistry (Amsterdam, Netherlands)·2000
Same author

[Outstanding efficacy of a macrolide in a small dosage for the treatment of refractory skin fistula communicating with the thoracic cavity and accompanying pyothorax].

The Japanese journal of antibiotics·2000
Same author

Effects of the mycelial extract of cultured Cordyceps sinensis on in vivo hepatic energy metabolism and blood flow in dietary hypoferric anaemic mice.

The British journal of nutrition·2000
Same author

Production of 105Rh-EDTMP and its bone accumulation.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2000
Same author

Prevention of hemorrhage from intradiverticular ulcer in the duodenum by Helicobacter pylori eradication.

The American journal of gastroenterology·2000
Same author

Surgical repair of a depressed fracture in a green sea turtle, Chelonia mydas.

The Journal of veterinary medical science·2000

Area of Science:

  • Environmental Science
  • Analytical Chemistry
  • Occupational Health

Background:

  • Accurate air sampling is crucial for assessing workplace exposure to volatile organic compounds.
  • Existing air sampling methods may have limitations in terms of flow rate consistency and portability.
  • Development of simple, reliable devices for monitoring organic solvent vapor is needed.

Purpose of the Study:

  • To evaluate a glass syringe equipped with disposable membrane filters as a constant-flow air sampling device.
  • To determine the feasibility of this device for measuring organic solvent vapor concentrations in the parts per million (ppm) range.

Main Methods:

  • A 100 ml glass syringe was utilized with 0.50-micron pore size Teflon membrane filters as a flow restrictor.
  • The device was tested for flow rate constancy over a 15-minute sampling period.

Related Experiment Videos

  • Gas chromatography with thermal desorption was employed for organic solvent vapor determination.
  • Main Results:

    • The air sampling device achieved a constant flow rate of 3 ml/min.
    • Using two to eight membrane filters ensured a stable flow rate for the entire sampling duration.
    • A sample volume under 50 ml was sufficient for detecting organic solvent vapors at ppm levels.

    Conclusions:

    • The glass syringe air sampler with disposable membrane filters is a viable tool for constant-flow air sampling.
    • This method is suitable for determining time-weighted average concentrations of organic solvent vapor in occupational settings.
    • The device offers a straightforward and effective approach for workplace air quality monitoring.